21 research outputs found

    Habituation deficit of visual evoked potentials in migraine patients with hypermobile Ehlers-Danlos syndrome

    Get PDF
    Objectives: Migraine is one of the most frequent clinical manifestations of hypermobile Ehlers-Danlos syndrome (hEDS). The comorbidity between these two diseases has been only partially investigated. We aimed to observe whether neurophysiological alterations described in migraineurs in visual evoked potentials (VEPs) were present in hEDS patients with migraine. Methods: We enrolled 22 hEDS patients with migraine (hEDS) and 22 non-hEDS patients with migraine (MIG), with and without aura (according to ICHD-3), as well as 22 healthy controls (HC). Repetitive pattern reversal (PR)-VEPs were recorded in basal conditions in all participants. During uninterrupted stimulation, 250 cortical responses were recorded (4,000 Hz sample rate) and divided into epochs of 300 ms after the stimulus. Cerebral responses were divided into five blocks. The habituation was calculated as the slope interpolating the amplitudes in each block, for both the N75-P100 and P100-N145 components of PR-VEP. Results: We observed a significant habituation deficit of the P100-N145 component of PR-VEP in hEDS compared to HC (p = 0.002), unexpectedly more pronounced than in MIG. We observed only a slight habituation deficit of N75-P100 in hEDS, with a slope degree that was intermediate between MIG and HC. Discussion: hEDS patients with migraine presented an interictal habituation deficit of both VEPs components like MIG. Pathophysiological aspects underlying the pathology could account for the peculiar pattern of habituation in hEDS patients with migraine characterized by a pronounced habituation deficit in the P100-N145 component and a less clear-cut habituation deficit in the N75-P100 component with respect to MIG

    Fifteen years of wireless sensors for balance assessment in neurological disorders

    Get PDF
    Balance impairment is a major mechanism behind falling along with environmental hazards. Under physiological conditions, ageing leads to a progressive decline in balance control per se. Moreover, various neurological disorders further increase the risk of falls by deteriorating specific nervous system functions contributing to balance. Over the last 15 years, significant advancements in technology have provided wearable solutions for balance evaluation and the management of postural instability in patients with neurological disorders. This narrative review aims to address the topic of balance and wireless sensors in several neurological disorders, including Alzheimer's disease, Parkinson's disease, multiple sclerosis, stroke, and other neurodegenerative and acute clinical syndromes. The review discusses the physiological and pathophysiological bases of balance in neurological disorders as well as the traditional and innovative instruments currently available for balance assessment. The technical and clinical perspectives of wearable technologies, as well as current challenges in the field of teleneurology, are also examined

    Narrative review of multiparametric ultrasound in parotid gland evaluation

    Get PDF
    Disorders affecting parotid gland represent a heterogeneous group comprising congenital, inflammatory and neoplastic diseases which show a focal or diffuse pattern of appearance. The differentiation of neoplastic from non-neoplastic conditions of parotid glands is pivotal for the diagnostic imaging. Frequently there is evidence of overlapping between the clinical and the imaging appearance of the various pathologies. The parotid gland is also often object of study with the combination of different techniques [ultrasound-computed tomography-magnetic resonance imaging (US-CT-MRI), ex.]. Compared to other dominant methods of medical imaging, US has several advantages providing images in real-time at lower cost, and without harmful use of ionizing radiation and of contrast enhancement. B-mode US, and the microvascular pattern color Doppler are usually used as first step evaluation of parotid lesions. Elastography and contrast-enhanced US (CEUS) has opened further possible perspectives to improve the differentiation between benign and malignant parotid lesions. The characterization of the parotid tumors plays a crucial role for their treatment planning and for the prediction of possible surgical complications. We present, here an updated review of the most recurrent pathologies of parotid gland focusing on the diagnostic power of multiparametric US including CEUS and ultrasound elastography (USE); limitations, advantages and the main key-points will be presented

    AN ABDOMINAL MASS IN A CHILD WITH IGA DEFICIENCY

    No full text
    Introduction: We describe for the first time the case of a one-year old girl admitted to our hospital on the suspicion of an abdominal tumor who finally received the diagnosis of celiac disease and IgA deficiency. Case presentation: A one-year old girl was admitted to the Pediatric Emergency Care Unit for severe bloating, diarrhea and vomiting for one month; she had been febrile for the last three days. Clinical examination revealed no guarding, a bloated and tender abdomen, and a palpable mass in the umbilical region. Abdominal ultrasonography was then performed, which identified a retroperitoneal mass resembling a tumor; therefore, she was transferred to the Paediatric Oncology Unit for further evaluations. Although deficit of serum IgA delayed the diagnosis, IgG serological markers (anti-deamidated gliadin peptide and anti-transglutaminase antibodies) and duodenal biospy confirmed celiac disease. She was discharged after 23 days on a gluten free diet. The patient was in good health and thriving normally at 12-month follow-up. Conclusion: Celiac disease can mimic several conditions whose differential diagnoses could be wide. In this case, both IgA deficiency and malnutrition could have led to multiple mesenteric lymphadenopathies, completely regressed once the gluten-free diet was started. If unrecognized, IgA deficiency can jeopardize CD diagnosis since anti-tissue transglutaminase and anti-endomysial antibodies are commonly tested as IgA antibodies. Physicians should always be aware of this association and ascertain IgA serum levels when assessing CD serological markers: if a IgA deficiency is present, demanding for specific IgG serological tests is then mandatory

    Timed Up and Go evaluation with wearable devices: Validation in Parkinson's disease

    No full text
    The Timed Up and Go test (TUG) is used to assess individual mobility. It evaluates static and dynamic balance by means of the total time required to complete the test, usually measured by a stopwatch. In recent years tools based on portable inertial measurement units (IMU) for clinical application are increasingly available on the market. More specifically, a tool (hardware and dedicated software) to quantify the TUG test based on IMU is now available. However, it has not yet been validated in subjects with Parkinson's disease (PD). Thus, the aim of this study is to compare measurements from instrumented TUG tests (or iTUG) acquired by an IMU with those obtained using an optoelectronic system (the gold standard) and by a stopwatch, to gain an in-depth understanding of IMU behavior in computing iTUG in subjects with PD. To do this, three TUG test trials were carried out on 30 subjects with PD and measured with all three systems simultaneously. System agreements were evaluated using Intraclass Correlation Coefficient and Bland-Altman plots. The device tested showed excellent reliability, accuracy and precision in quantifying total TUG test duration. Since TUG is a widely used test in rehabilitation settings, its automatic quantification through IMUs could potentially improve the quality of assessments in the quantification of PD gait ability

    Timed Up and Go evaluation with wearable devices: Validation in Parkinson's disease

    No full text
    The Timed Up and Go test (TUG) is used to assess individual mobility. It evaluates static and dynamic balance by means of the total time required to complete the test, usually measured by a stopwatch. In recent years tools based on portable inertial measurement units (IMU) for clinical application are increasingly available on the market. More specifically, a tool (hardware and dedicated software) to quantify the TUG test based on IMU is now available. However, it has not yet been validated in subjects with Parkinson's disease (PD). Thus, the aim of this study is to compare measurements from instrumented TUG tests (or iTUG) acquired by an IMU with those obtained using an optoelectronic system (the gold standard) and by a stopwatch, to gain an in-depth understanding of IMU behavior in computing iTUG in subjects with PD. To do this, three TUG test trials were carried out on 30 subjects with PD and measured with all three systems simultaneously. System agreements were evaluated using Intraclass Correlation Coefficient and Bland-Altman plots. The device tested showed excellent reliability, accuracy and precision in quantifying total TUG test duration. Since TUG is a widely used test in rehabilitation settings, its automatic quantification through IMUs could potentially improve the quality of assessments in the quantification of PD gait ability
    corecore